Skip to main content
. 2022 Jan 10;24:5. doi: 10.1186/s12968-021-00839-9

Table 3.

Mean bias and upper and lower limits of agreement for co-axial aortic diameter measurements

Mean Bias Upper limit of agreement (+ 1.96 SD) Lower limit of agreement (− 1.96 SD)
Reviewer 2
 Aortic root − 0.03 0.18 − 0.24
 Sinotubular junction − 0.02 0.21 − 0.25
 Mid ascending aorta − 0.02 0.21 − 0.24
 Mid aortic arch 0.003 0.2 − 0.21
 Mid descending aorta − 0.02 0.15 − 0.2
 Distal descending aorta 0.03 0.2 − 0.13
Reviewer 3
 Aortic root − 0.02 0.29 − 0.31
 Sinotubular junction − 0.03 0.23 − 0.28
 Mid ascending aorta − 0.05 0.24 − 0.31
 Mid aortic arch 0.01 0.33 − 0.31
 Mid descending aorta 0.006 0.29 − 0.25
 Distal descending aorta − 0.02 0.2 − 0.25

Mean bias and upper and lower limits of agreement for co-axial aortic diameter measurements with iNAV versus dNAV approach for two reviewers