. 2022 Jan 4;19(1):525. doi: 10.3390/ijerph19010525

Table 2.

Details of the air samples’ collections for SARS-CoV-2 RNA detection in the Hospital.

Device Sample ID Date of Collection Hospital Area Sampler Location Sampling Parameters
Coriolis® Compact C1 21 January 2021 ICU COVID-19 Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 50 L/min, 60 min
C2 21 January 2021 ICU intermediate COVID-19 Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 50 L/min, 60 min
C3 21 January 2021 Nursing area COVID-19 Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 50 L/min, 60 min
C4 27 January 2021 Respiratory diseases observation room Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 50 L/min, 60 min
C5 27 January 2021 Respiratory diseases waiting room Air sampler placed approximately 1.3 m above the floor in the center of the room 50 L/min, 60 min
C6 27 January 2021 Clinical decision unit Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 50 L/min, 60 min
C7 2 February 2021 COVID-19 testing room Air sampler placed approximately 1.3 m above the floor in the center of the room 50 L/min, 60 min
C8 2 February 2021 Non-respiratory diseases waiting room Air sampler placed approximately 1.3 m above the floor in the center of the room 50 L/min, 60 min
C9 2 February 2021 Urgency Care (Recovery area) Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 50 L/min, 60 min
C10 11 February 2021 Hospital’s outside entrance atrium Air sampler placed approximately 1.3 m above the floor in the center of the room 50 L/min, 60 min
C11 11 February 2021 Hospital employe’s cafeteria Air sampler placed approximately 1.3 m above the floor in the center of the room 50 L/min, 60 min
Coriolis® μ M1 21 January 2021 ICU COVID-19 Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 100 L/min, 10 min
M2 21 January 2021 ICU COVID-19 Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 200 L/min, 10 min
M3 21 January 2021 ICU COVID-19 Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 300 L/min, 10 min
M4 21 January 2021 ICU intermediate COVID-19 Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 100 L/min, 10 min
M5 21 January 2021 ICU intermediate COVID-19 Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 200 L/min, 10 min
M6 21 January 2021 ICU intermediate COVID-19 Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 300 L/min, 10 min
M7 21 January 2021 Nursing area COVID-19 Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 100 L/min, 10 min
M8 21 January 2021 Nursing area COVID-19 Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 200 L/min, 10 min
M9 21 January 2021 Nursing area COVID-19 Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 300 L/min, 10 min
M10 27 January 2021 Respiratory diseases observation room Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 100 L/min, 10 min
M11 27 January 2021 Respiratory diseases observation room Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 200 L/min, 10 min
M12 27 January 2021 Respiratory diseases observation room Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 300 L/min, 10 min
M13 27 January 2021 Respiratory diseases waiting room Air sampler placed approximately 1.3 m above the floor in the center of the room 100 L/min, 10 min
M14 27 January 2021 Respiratory diseases waiting room Air sampler placed approximately 1.3 m above the floor in the center of the room 200 L/min, 10 min
M15 27 January 2021 Respiratory diseases waiting room Air sampler placed approximately 1.3 m above the floor in the center of the room 300 L/min, 10 min
M16 27 January 2021 Clinical decision unit Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 100 L/min, 10 min
M17 27 January 2021 Clinical decision unit Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 200 L/min, 10 min
M18 27 January 2021 Clinical decision unit Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 300 L/min, 10 min
M19 2 February 2021 COVID-19 testing room Air sampler placed approximately 1.3 m above the floor in the center of the room 100 L/min, 10 min
M20 2 February 2021 COVID-19 testing room Air sampler placed approximately 1.3 m above the floor in the center of the room 200 L/min, 10 min
M21 2 February 2021 COVID-19 testing room Air sampler placed approximately 1.3 m above the floor in the center of the room 300 L/min, 10 min
M22 2 February 2021 Non-respiratory diseases waiting room Air sampler placed approximately 1.3 m above the floor in the center of the room 100 L/min, 10 min
M23 2 February 2021 Non-respiratory diseases waiting room Air sampler placed approximately 1.3 m above the floor in the center of the room 200 L/min, 10 min
M24 2 February 2021 Non-respiratory diseases waiting room Air sampler placed approximately 1.3 m above the floor in the center of the room 300 L/min, 10 min
M25 2 February 2021 Urgency Care (Recovery area) Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 100 L/min, 10 min
M26 2 February 2021 Urgency Care (Recovery area) Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 200 L/min, 10 min
M27 2 February 2021 Urgency Care (Recovery area) Air sampler placed approximately 1.3 m above the floor and 2 m from a patient bed, in the center of the room 300 L/min, 10 min
M28 11 February 2021 Hospital’s outside entrance atrium Air sampler placed approximately 1.3 m above the floor in the center of the room 100 L/min, 10 min
M29 11 February 2021 Hospital’s outside entrance atrium Air sampler placed approximately 1.3 m above the floor in the center of the room 200 L/min, 10 min
M30 11 February 2021 Hospital’s outside entrance atrium Air sampler placed approximately 1.3 m above the floor in the center of the room 300 L/min, 10 min
M31 11 February 2021 Hospital staff’s cafeteria Air sampler placed approximately 1.3 m above the floor in the center of the room 100 L/min, 10 min
M32 11 February 2021 Hospital staff’s cafeteria Air sampler placed approximately 1.3 m above the floor in the center of the room 200 L/min, 10 min
M33 11 February 2021 Hospital staff’s cafeteria Air sampler placed approximately 1.3 m above the floor in the center of the room 300 L/min, 10 min