Skip to main content
. 2022 Jan 4;15(1):340. doi: 10.3390/ma15010340

Table 3.

The recommended values for rheological properties of SCC as per EFNARC guidelines.

Test Method Minimum-Maximum
Slump flow (mm) 650–800
T500 (S) 2–5
V-funnel (S) 6–12