Table 2.

Noncompartmental plasma pharmacokinetic parameters for ondansetron following IV dosing of 10 mg/kg in wild-type and Pgp knockout rats

Male Female*
Parameter Wild-type Knock-out Wild-type Knock-out
t1/2,plasma (h) 0.52 (0.01) 0.65 (0.04) 0.54 0.64
AUCplasma,0−∞ (h·μg·mL−1) 3.83 (0.64) 3.70 (0.49) 2.52 2.57
MRT (h) 0.47 (0.04) 0.47 (0.10) 0.76 0.72
Vd,ss (mL) 417 (98) 422 (124) 802 766
CL (mL·h−1) 869 (132) 892 (120) 1050 1029
*

In female rats, concentrations were obtained from terminal sampling; therefore, individual profiles were not available, and SD could not be calculated.