Skip to main content
. 2022 Jan 12;12:590. doi: 10.1038/s41598-021-04601-0

Table 4.

Comparison of dosimetric values of patients with and without radiation pneumonitis.

Variable Occurrence of grade ≥ 2 RP Occurrence of grade ≥ 3 RP
Patients with RP Patients without RP P-value Patients with RP Patients without RP P-value
Total lung
V5 (%) 52.5 ± 9.4 37.6 ± 15.0  < 0.01 49.8 ± 10.2 42.1 ± 15.5 0.20
V20 (%) 24.1 ± 5.3 16.1 ± 6.8  < 0.01 21.6 ± 5.2 18.6 ± 7.6 0.26
V40 (%) 13.2 ± 4.2 7.9 ± 4.8  < 0.01 11.7 ± 4.7 9.6 ± 5.3 0.24
Contralateral lung
V5 (%) 33.4 ± 14.1 25.9 ± 18.4 0.10 30.5 ± 16.6 28.5 ± 17.4 0.83
V20 (%) 6.1 ± 5.5 5.1 ± 6.4 0.19 4.5 ± 5.3 5.7 ± 6.2 0.82
V40 (%) 1.9 ± 2.4 1.6 ± 2.8 0.27 1.4 ± 2.1 1.8 ± 2.7 0.68

RP radiation pneumonitis, V5 lung volume receiving a dose of ≥ 5 Gy, V20 lung volume receiving a dose of ≥ 20 Gy, V40 lung volume receiving a dose of ≥ 40 Gy.