Skip to main content
. Author manuscript; available in PMC: 2023 Jan 1.
Published in final edited form as: Med Phys. 2021 Nov 27;49(1):41–51. doi: 10.1002/mp.15351

TABLE III:

Results of the slice-by-slice analysis of each method to compare the robustness of each method. The number of slices, along with the percentage of slices, falling within the given thresholds are shown. The best results are highlighted in bold

Linear Interpolation (LI) Automatic Segmentation (FAS) MAI Algorithm
Stomach # DSC <0.8 184 (30%) 175 (28%) 44 (7%)
# MSD >3 mm 377 (61%) 312 (50%) 159 (26%)
Bowel # DSC <0.8 236 (46%) 305 (60%) 80 (16%)
# MSD >3 mm 231 (45%) 361 (71%) 105 (21%)