Table 3.

Overall agreement between MSD and commerical serology assays.

Assays a Overall agreement % (95% CI) Overall agreement % (95% CI) Overall agreement % (95% CI)
MSD N vs Abbott (N) (n = 316) 97.5 (97.1–97.9) 95.7 (94.8–96.6) 98.2 (97.8–98.6)
MSD S vs EUROIMMUN (S) (n = 310) 92.6 (91.9–93.3) 90.4 (89.0–91.8) 93.5 (92.8–94.3)
MSD RBD vs EUROIMMUN (S) (n = 310) 95.2 (94.6–95.7) 90.4 (89.0–91.8) 97.2 (96.7–97.7)
MSD S vs Siemens (RBD) (n = 301) 94.0 (93.4–94.6) 91.8 (90.4–93.1) 94.9 (94.2–95.6)
MSD RBD vs Siemens (RBD) (n = 301) 96.4 (95.9–96.8) 90.6 (89.1–92.0) 98.6 (98.3–99.0)
a

IgG antibodies detected in the MSD multiplex assay were compared with the results obtained from the commercial serology assays directed against individual antigens.