Skip to main content
. 2022 Jan 20;147:105080. doi: 10.1016/j.jcv.2022.105080

Table 1.

m2000 and Alinity m SARS-CoV-2 assay results with B.1.1.7, B.1.351, and P.1 virus culture dilutions.

Sample ID+ TCID50/mL Log GE/mL* RealTime SARS-CoV-2 Alinity m SARS-CoV-2 Alinity m Resp-4-Plex
B.1.1.7 variant BEI NR-54,011 Dilution 1 28 6.25 Detected Detected Detected
BEI NR-54,011 Dilution 2 2.8 5.19 Detected Detected Detected
BEI NR-54,011 Dilution 3 0.28 4.00 Detected Detected Detected
BEI NR-54,011 Dilution 4 0.028 2.85 Detected Detected Detected
B.1.351 variant BEI NR-54,008 Dilution 1 28 4.63 Detected Detected Detected
BEI NR-54,008 Dilution 2 2.8 3.83 Detected Detected Detected
BEI NR-54,008 Dilution 3 0.28 2.51 Detected Detected Detected
BEI NR-54,008 Dilution 4 0.028 1.27 Detected Detected Detected
BEI NR-54,009 Dilution 1 28 4.35 Detected Detected Detected
BEI NR-54,009 Dilution 2 2.8 3.27 Detected Detected Detected
BEI NR-54,009 Dilution 3 0.28 2.11 Detected Detected Detected
BEI NR-54,009 Dilution 4 0.028 0.73 Detected Detected Detected
P.1 variant BEI NR-54,982 Dilution 1 28 4.56 Detected Detected Detected
BEI NR-54,982 Dilution 2 2.8 3.45 Detected Detected Detected
BEI NR-54,982 Dilution 3 0.28 2.39 Detected Detected Detected
BEI NR-54,982 Dilution 4 0.028 1.32 Detected Detected Detected

Log genome equivalents (GE)/mL were calculated from a standard curve plot of TCID50 vs GE with an R2 value of 0.99. Four out of four replicates were detected for all dilutions tested.