Table 2.

Summary of some eMIP-based sensors for clinically relevant biomarker, featuring polymer matrix, electrochemical detection method, linear concentration range and detection limit.

Target MIP Electrode Material Detection Method Linear Centration Range LOD Reference
gp51 Ppy Pt PDA (Photodiode-Array) - - [107]
B. subtilis endospores Ppy/poly (3-methylthiophene) GCE EIS (electrochemical impedance spectroscopy) 104–106 CFU/mL 102 CFU/mL [108]
EP PAPBA MWCNTs/GCE DPV (differential pulse voltammetry) 0.2–800 µM 35 nM [109]
Insulin PPD GCE DPV 10−14–5 · 10−13 M 7.24 10−15 M [71]
BuCHE PPD GCE CV, amperometry 0.05–2 nM 14.7 pM [110]
VEGF PPD SPE EIS 20–200 pg/mL 0.08 pg/mL [111]
ncovNP PPD Au-TFE DPV ≤111 fM 15 fM [112]
dopamine poly(o-aminophenol) Au DPV 20–250 nM 1.98 nM [113]
NE poly(o-aminophenol) GCE SWV 0.05–10 µM 0.49 nM [114]
CA15-3 poly(2-aminophenol) AuSPE DPV 5–50 U/mL 1.5 U/mL [90]
HER2-ECD polyphenol AuSPE DPV 10–70 ng/mL 1.6 ng/mL [115]
3-NT polyphenol Paper-based with carbon ink DPV 500 nM–1 mM 22.3 nM [116]
cyt c polyscopoletin Au/MUA CV, chronoamperometry - - [117]