Table 3.

Permeability parameters of clindamycin in hydrogel formulations.

Formulation Linear Regression Equation Coefficient of Determination, R2 Steady-State Flux, Jss
[µg/cm2/h]
Permeability Coefficient, Pm
[cm/h × 103]
Enhancement Factor (EF)
C1 y = 43.64x + 6.2349 0.9874 43.64 3.862 1
C2 y = 117.86x + 69.187 0.9953 117.86 10.430 1
G1 y = 63.56x + 11.263 0.9774 63.56 5.625 1.46 *
G2 y = 64.36x − 12.872 0.9903 64.36 5.695 1.47 *
G3 y = 73.61x + 33.387 0.9914 73.61 6.514 1.69 *
G4 y = 76.03x + 67.981 0.9810 76.03 6.728 1.74 *
G5 y = 133.55x + 79.646 0.9878 133.55 11.819 1.13 **
G6 y = 135.16x + 85.278 0.9936 135.16 11.961 1.15 **
G7 y = 147.63x + 56.718 0.9940 147.63 13.065 1.25 **
G8 y = 159.29x + 74.819 0.9942 159.29 14.096 1.35 **

* vs. C1; ** vs. C2.