Table 7.
Statistics of radiological parameters in the municipalities of Caprarola, Celleno and Ciampino. Inhalation dose (D) calculated from IRC using Equation (1); AEDE, Annual Effective Dose Equivalent, calculated from indoor and outdoor gamma radiation using Equation (2); ELCR, Excess Lifetime Cancer Risks calculated using Equation (3) * [48].
Municipality | Inhalation Dose (D) (mSv/y) (Min–Max) | AEDEin (mSv/y) (Min–Max) | AEDEout (mSv/y) (Min–Max) | ELCRin (×10−3) (Min–Max) | ELCRout (×10−3) (Min–Max) |
---|---|---|---|---|---|
Caprarola | 12.06 (0.16–91.05) | 3.04 (0.74–9.92) | 0.64 (0.27–1.70) | 11.71 (2.87–38.19) | 2.55 (1.08–6.80) |
Celleno | 8.11 (0.35–39.43) | 2.06 (0.92–4.03) | 0.40 (0.23–0.73) | 7.94 (3.55–15.50) | 1.60 (0.91–2.91) |
Ciampino | 5.18 (0.70–23.35) | 1.24 (0.44–2.68) | 0.26 (0.18–0.41) | 4.77 (1.70–10.33) | 1.03 (0.73–1.65) |
World average * | 3.50 | 0.45 | 0.11 | 1.16 | 0.29 |