Skip to main content
. 2022 Jan 8;15(2):476. doi: 10.3390/ma15020476

Table 5.

Circuit parameters calculated from the fitting of the EIS spectra at corrosion potential to the equivalent circuit from Figure 10b.

Alloy Rs
(Ω·cm2)
Y0p·105
(S·sn/cm2)
0 < n < 1
no Rl
(Ω·cm2)
Y0c·105
(S·sn/cm2)
0 < n < 1
nc Rc
(kΩ·cm2)
χ2·104
Ti–5Ta 34.2 1.72 0.59 500.6 2.71 0.89 153.1 7.24
Ti–15Ta 59.0 9.90 0.78 887.5 17.6 0.91 322.4 4.37
Ti–25Ta 11.5 1.74 0.72 14.5 4.31 0.94 577.3 4.89
Ti–30Ta 27.1 6.13 0.79 28.1 1.10 0.90 485.9 1.88