Table 3.

Potential causes of inconsistencies between planar 99mTc‐PYP scintigraphy and biopsy findings in suspected ATTR‐CM

Planar 99mTc‐PYP scintigraphy Biopsy Potential causes of inconsistencies
Positive Negative
  • Sampling errors in biopsy

  • Errors in scintigraphy imaging time or evaluation

  • Errors in pathological diagnosis

  • Cardiac pools

  • Deposit of proteins other than transthyretin (e.g. AL)

Negative Positive
  • Errors in scintigraphy evaluation

  • Errors in pathological diagnosis

  • Deposit of proteins other than transthyretin (e.g. AL)

  • ATTRv‐CM with a low sensitivity in 99mTc‐PYP scintigraphy (Phe64Leu mutation)

A positive 99mTc‐PYP scintigraphy result refers to Grade 2 (moderate cardiac uptake equal to rib uptake) or Grade 3 (high cardiac uptake greater than rib uptake), and a negative result refers to Grade 0 (no cardiac uptake) or Grade 1 (mild cardiac uptake less than rib uptake).

99mTc‐PYP, 99mtechnetium‐pyrophosphate; AL, light chain; ATTR‐CM, transthyretin amyloid cardiomyopathy; ATTRv‐CM, variant ATTR‐CM.