Skip to main content
. 2022 Jan 25;17(1):e0263025. doi: 10.1371/journal.pone.0263025

Table 2. LAMP assays for detection of SARS-CoV-2 RNA on money cards on Brigham Young University (BYU) campus.

Date collected COVID cases per 100,000 (daily)* # assayed # LAMP positive (%)** # Plaque assay positive (%)
11/17/2020 122.3 (79.4) 110 8 (7.2%) -
12/11/2020 92.1 (99.8) 90 3 (3.3%) -
2/19/2021 29.4 (22.8) 79 6 (7.6%) 0***
Totals: 279 17 (2.6%)

*Active, laboratory confirmed, 7-day average COVID cases from Utah County as declared from the local health department (daily rate in parenthesis).

**Positive samples are positives from an initial assay that were verified in a secondary assay. LAMP assays were conducted using the SARS-CoV-2 Rapid Colorimetric LAMP Assay Kit (New England Biolabs).

***A total of 14 samples, including all 6 positive samples and 8 negatives from the 2/19/2021 testing were assayed in the BSL-3 laboratory for live virus using a dilution series starting at 1:4. No plaques were seen for any of the samples. A viable suspension of SARS-CoV-2 with a titer of 7.75x106 pfu/ml was used as a positive control. “-”is not determined.