Skip to main content
. 2022 Jan 25;12:1305. doi: 10.1038/s41598-022-05413-6

Table 1.

IRIF numbers, cell volume and analyzed number of cells for 1.9 Gy and 3.0 Gy of gamma irradiation for all time points. Uncertainties represent the standard error of the mean.

Dose Time (min) 53BP1 DNA-PKcs Cell volume (µm3) Number of cells
#IRIF/cell #IRIF/µm3 #IRIF/cell #IRIF/µm3
0 Gy 5 ± 4 0.007 ± 0.006 4 ± 4 0.006 ± 0.006 723 ± 100 20
1.9 Gy 3 32.7 ± 2.6 0.039 ± 0.004 35.4 ± 2.5 0.043 ± 0.006 864 ± 55 14
5 29.7 ± 3.7 0.044 ± 0.005 35.9 ± 4.8 0.052 ± 0.005 685 ± 79 14
10 30.5 ± 3.6 0.042 ± 0.009 35.1 ± 5.1 0.0486 ± 0.011 843 ± 108 20
30 27.7 ± 2.8 0.0292 ± 0.0018 29.3 ± 2.5 0.0312 ± 0.0013 964 ± 111 18
3.0 Gy 3 39.5 ± 2.5 0.060 ± 0.004 43.1 ± 2.5 0.064 ± 0.003 675 ± 57 18
5 35.0 ± 3.0 0.073 ± 0.009 35.3 ± 2.9 0.073 ± 0.009 531 ± 65 20
10 33.3 ± 2.5 0.060 ± 0.005 35.2 ± 2.4 0.064 ± 0.005 567 ± 36 20
30 39.2 ± 4.8 0.062 ± 0.006 39.9 ± 4.7 0.063 ± 0.006 660 ± 91 18