Skip to main content
. 2022 Jan 20;3(1):101115. doi: 10.1016/j.xpro.2021.101115

Table 2.

Stimulation protocols

Protocol Description No. of increasing stimulus intensities No. of repetitions per intensity
Input-output (I/O) 1× square pulse @ 0.06 Hz 5–10 intensities 5–10 once every 15 s
Short-term plasticity (STP) 3× square pulses @ 50 Hz 1–3 intensities 3–8 once every 30 s