. 2001 Apr;39(4):1289–1293. doi: 10.1128/JCM.39.4.1289-1293.2001

TABLE 3.

Accuracy of diagnostic tests for R. equi pneumonia

Reference standard test Diagnostic testa Sensitivity (%) Specificity (%) Disease prevalenceb
TW fluid culture PCR (VP) 90.0 81.4 10/53 (18.9)
PCR (VP, 16S) 70.0 88.4 10/53 (18.9)
AGID 75.0 80.0
Final clinical diagnosis TW fluid PCR (VP) 100.0 90.6 14/46 (30.4)
TW fluid PCR (16S) 78.6 68.8 14/46 (30.4)
TW fluid PCR (VP, 16S) 78.6 96.9 14/46 (30.4)
TW fluid culture 57.1 93.8 14/46 (30.4)
AGID 62.5 75.9 8/37 (21.6)
Nasal swab PCR (VP) 50.0 88.9 6/33 (18.2)
Serum PCR (VP) 12.5 88.9 8/35 (22.9)
Buffy coat PCR (VP) 11.1 86.7 9/39 (23.1)
a

VP, PCR positive using VP primers; 16S, PCR positive using 16S primers. 

b

Number of foals positive with the reference standard test divided by the total number of foals with results available for both the reference standard test and the diagnostic test being evaluated. (Values in parentheses are percentages.)