FIGURE 2.

(A) Electrocardiogram monitoring detected QRS wave loss. Arrows indicate dropped QRS wave. (B) ECG on admission to the ICU showing Mobitz type II atrioventricular block with QRS wave loss and RR intervals of up to less than 2 s. The PR interval in the conducted beats remained constant (PR=280 msec). “P” indicates P wave