Constant parameters of molecular weight equation for FVP solution under different ultrasound intensities.

Ultrasonic intensities (W/cm2) 0 order 1st order 2nd order
k0 R2 k1 (min−1) R2 k2 (mol·g−1·min−1) R2
531 0.324 0.961 0.767 × 10-2 0.977 1.829 × 10-4 0.988
1062 0.466 0.958 1.325 × 10-2 0.986 3.882 × 10-4 0.997
1592 0.496 0.926 1.572 × 10-2 0.973 5.205 × 10-4 0.996
2123 0.488 0.938 1.623 × 10-2 0.977 5.714 × 10-4 0.995
2654 0.478 0.931 1.656 × 10-2 0.975 6.019 × 10-4 0.997
3185 0.475 0.929 1.665 × 10-2 0.978 6.131 × 10-4 0.999