Table 4.
Sampling site | Sampling method | PCR | PCR positivity cycle | PCR challenge test |
---|---|---|---|---|
Patients bed side table | Wipe | positive | 26.4 | positive (37.3) |
patients dining table | Wipe | positive | 37.6 | negative |
patients service table | Wipe | positive | 38.2 | negative |
table away from patients | Wipe | negative | >40 | negative |
Close air (<50 cm) at patients at 1.5 m of height | bubbler sampling | positive | 25.2 | positive (35.1) |
Far air (>2 m) at patients at 1.5 m of height | bubbler sampling | positive | 36.6 | negative |
Distant air (>2 m) at a height of 2.5 m near the air intake vent | bubbler sampling | negative | >40 | negative |
NT, not tested.
Notes: Boundary conditions on the day of sampling 21-04-2021.
- Positive patients present in the ward: 13.
- Positive patients present in the room where the samples were taken: 7.
- Volume of the room: 165 m3
- Air volume per patient: 24 m3
- Indoor thermohygrometric conditions: T 22.8 °C - R.H. 49.8%.
- No mechanical ventilation.
- Natural ventilation estimated at 0.5 vol/h.