Skip to main content
. 2020 Feb;61(2):234–241. doi: 10.2967/jnumed.119.233064

TABLE 1.

Physical and Photophysical Characteristics of PSMA-Targeted Hybrid Tracers

Compound λex,maxem,max in H2O/PBS (nm) ΦF (% in PBS) Brightness (×104 M−1 × cm−1 in PBS) Lipophilicity (logP(o/w); n = 6)* PPB (n = 3) Serum stability after 24 h (% remaining; n = 2)
EuK-Cy5-mas3 644/663 (18) 12 1.1 −2.13 ± 0.10 88.3 ± 1.6 Abs: 80 ± 6/Flu: 86 ± 5
EuK-(SO3)Cy5-mas3 648/664 (16) 15 1.4 −2.86 ± 0.05 85.0 ± 2.3 Abs: 97 ± 2/Flu: 89 ± 6
EuK-Cy5(SO3)-mas3 648/664 (16) 10 1.5 −2.70 ± 0.01 87.4 ± 2.0 Abs: 82 ± 7/Flu: 85 ± 1
EuK-(Ar)Cy5-mas3 664/682 (18) 9 0.3 −1.75 ± 0.10 90.7 ± 1.3 Abs: 85 ± 3/Flu: 79 ± 1
EuK-Cy5(Ar)-mas3 663/680 (17) 12 0.7 −1.84 ± 0.06 89.0 ± 2.5 Abs: 75 ± 0/Flu: 76 ± 0

Calculated using molecular extinction coefficient of free fluorophore.

*

Measured using 99mTc-labeled hybrid tracers.

Parenthetic numbers are Stokes shift.

λex,maxem,max = maximum λexem; ΦF = quantum yield; logP(o/w) = the partition coefficient in octanol/water; PBS = phosphate-buffered saline; Abs = absorbance; Flu = fluorescence.