Table 2.
Association Analysis of IOP With Ocular Geometric Parameters in Phakic Eyes
N = 13,280 Eyes | Univariable | Multivariable (R2 = 0.25) | ||||||
---|---|---|---|---|---|---|---|---|
Parameter | B | 95% CI | P Value | R2 | B | 95% CI | P Value | B Per SD |
Sex, female | 0.122 | 0.001; 0.244 | 0.050 | 0.042 | ||||
Age, 10 years | 0.196 | 0.133; 0.259 | <0.0001 | 0.068 | ||||
CCT, mm | 0.0418 | 0.0400; 0.0436 | <0.001 | 0.24 | 0.042 | 0.0401; 0.0437 | <0.0001 | 0.478 |
Anterior chamber depth, mm | 0.008 | −0.175; 0.190 | 0.93 | 0.000 | −0.015 | −0.234; 0.205 | 0.90 | −0.002 |
Mean corneal curvature, mm | 0.742 | 0.495; 0.989 | <0.001 | 0.006 | −0.192 | −0.431; 0.048 | 0.12 | −0.017 |
Lens thickness, mm | 0.388 | 0.244; 0.531 | <0.001 | 0.007 | 0.252 | 0.084; 0.421 | 0.0033 | 0.010 |
Posterior segment length, mm | 0.138 | 0.087; 0.188 | <0.001 | 0.001 | 0.199 | 0.144; 0.254 | <0.0001 | 0.077 |
Data from the Gutenberg Health Study (2012–2017).
Linear regression analysis with generalized estimating equations (GEE). R2 describe the a pseudo R2 and does not take into account the correlation structure of the GEE model.
CCT, central corneal thickness.