Table 3.
Association Analysis of IOP and Anterior Chamber Angle width in Phakic Eyes Incorporating Parameters of the Anterior Segment
N = 13.280 | Multivariable (R2 = 0.26) | ||
---|---|---|---|
Parameter | B | 95% CI | P Value |
Sex, female | 0.124 | 0.003; 0.246 | 0.047 |
Age, 10 years | 0.201 | 0.137; 0.264 | <0.0001 |
CCT, mm | 0.0422 | 0.040; 0.044 | <0.0001 |
Anterior chamber depth, mm | 0.113 | −0.133; 0.359 | 0.37 |
Mean corneal curvature, mm | −0.176 | −0.417; 0.065 | 0.15 |
Lens thickness, mm | 0.446 | 0.275; 0.617 | <0.0001 |
Posterior segment length, mm | 0.197 | 0.142; 0.252 | <0.0001 |
Anterior chamber angle, in degrees | 0.007 | −0.008; 0.022 | 0.34 |
Data from the Gutenberg Health Study (2012–2017).
Linear regression analysis with generalized estimating equations (GEEs).
CCT, central corneal thickness.
R2 describe the a pseudo R2 and does not take into account the correlation structure of the GEE model.