The results of the spalling test for CR and CF concrete.

Sample No. initial mass,[g] exfoliated material, [g] exfoliatedmaterial, [%] exfoliated materal - mean value, [%]
CR 1 367.68 0.97 0.26 0.24
2 371.98 1.17 0.31
3 358.15 0.46 0.13
4 348.91 0.88 0.25
CF 1 356.65 0.59 0.17 0.21
2 372.98 0.99 0.27
3 385.14 1.13 0.29
4 353.78 0.46 0.13