Skip to main content
. 2022 Jan 27;2022:9926635. doi: 10.1155/2022/9926635

Table 1.

Left ventricular functional parameters of rats on 31st day.

Control DOX DOX+QL
LVEDd (mm) 6.11 ± 0.23 6.53 ± 0.40 6.49 ± 0.22
LVEDs (mm) 2.55 ± 0.11 4.42 ± 0.29∗∗∗ 3.61 ± 0.26#
LVPWd (mm) 1.67 ± 0.10 1.67 ± 0.07 1.85 ± 0.12
LVPWs (mm) 3.09 ± 0.20 2.25 ± 0.12 3.02 ± 0.16#
LVAWd (mm) 1.84 ± 0.09 1.58 ± 0.09 1.71 ± 0.11
LVAWs (mm) 3.19 ± 0.11 2.40 ± 0.15∗∗∗ 2.67 ± 0.16
FS (%) 58.20 ± 1.38 32.43 ± 1.77∗∗∗ 44.71 ± 2.92##
EF (%) 91.50 ± 0.69 66.29 ± 2.39∗∗∗ 80.29 ± 2.93###

Data are presented as mean ± SD. DOX vs. control P < 0.05 and ∗∗∗P < 0.001. DOX+QL vs. DOX #P < 0.05, ##P < 0.01, and ###P < 0.001 by two-way repeated-measures ANOVA with LSD post hoc test. LVEDd: left ventricular end-diastolic diameter; LVEDs: left ventricular end-systolic diameter; LVPWd: left ventricular posterior wall thickness in end-diastole; LVPWs: left ventricular posterior wall thickness in end-systole; LVAWd: left ventricular anterior wall thickness in end-diastole; LVAWs: left ventricular anterior wall thickness in end-systole; EF: left ventricular ejection fraction; FS: left ventricular fractional shortening.