Skip to main content
. 2022 Feb 5;14:17. doi: 10.1186/s13102-022-00408-2

Table 2.

Evidence assessment of outcomes

Outcomes Anticipated absolute effects (95% CI) Patients (studies) Quality of evidence Rated down reasons
Function ability 0.25 MD lower (0.38–0.11 lower) 735 (11 RCTs) ⨁⨁⨁◯ Moderate Inconsistency
Disease activity 0.55 MD lower (1.12 lower to 0.01 higher) 573 (8 RCTs) ⨁⨁◯◯ Low Inconsistency; imprecision
Joint counts 0.59 MD lower (1.26 lower to 0.07 higher) 305 (4 RCTs) ⨁⨁◯◯ Low Inconsistency; imprecision
CRP 1.08 MD lower (2.20 lower to 0.05 higher) 298 (5 RCTs) ⨁⨁◯◯ Low Inconsistency; imprecision
ESR 0.76 SMD lower (1.67 lower to 0.14 higher) 305 (5 RCTs) ⨁⨁◯◯ Low Inconsistency; imprecision
pain 0.46 SMD lower (0.90–0.01 lower) 247 (4 RCTs) ⨁⨁⨁◯ Moderate Imprecision
Aerobic capacity 2.41 MD higher (1.36–3.45 higher) 247 (5 RCTs) ⨁⨁◯◯ Low Inconsistency; imprecision
STS test 1.60 MD higher (0.07–3.13 higher) 122 (2 RCTs) ⨁⨁◯◯ Low Inconsistency; imprecision