Skip to main content
. 2022 Feb;33(2):420–430. doi: 10.1681/ASN.2021030404

Table 3.

Reference standard and predicted volumes for each structure considered in this study for the patients in the Mayo Clinic Minnesota test and validation set. The statistics reported are mean±SD and range (min/max) and the P values for difference

Label Manual Segmentation Automated Segmentation P Value
Right cortex, cc Test
n=386
103.5±22.4
(53.3/177.7)
104.4±21.7
(53.8/180.2)
>0.05
Validation
n=306
103.7±22.6
(58.0/174.9)
104.7±21.9
(61.4/181.0)
>0.05
Left cortex, cc Test
n=386
104.5±23.6
(51.5/182.4)
105.6±23.3
(53.0/193.6)
>0.05
Validation
n=306
104.2±22.2
(49.8/184.2)
105.2±21.5
(51.1/187.6)
>0.05
Right medulla, cc Test
n=386
42.6±11.1
(15.3/85.5)
42.5±10.5
(16.7/78.6)
>0.05
Validation
n=306
43.3±11.7
(11.7/90.7)
43.05±11.3
(19.5/81.4)
>0.05
Left medulla, cc Test
n=386
39.5±10.6
(15.2/77.8)
39.4±10.1
(16.8/74.0)
>0.05
Validation
n=306
39.8±10.5
(16.8/80.5)
39.5±10.4
(15.2/80.4)
>0.05