Skip to main content
. 2022 Jan 24;9(1):e24699. doi: 10.2196/24699

Table 3.

Diagnostic classification.

Features AUROCa Accuracy Accuracy chance F score




Schizophrenia spectrum disorders Bipolar disorder
Voice 0.65 0.71 0.55 0.80 0.46
Face 0.68 0.72 N/Ab 0.80 0.56
Face and voice 0.73 0.72 N/A 0.80 0.56

aAUROC: area under the receiver operating characteristic curve.

bN/A: not applicable.