Table 1. Cryo-EM data collection, refinement, and validation statistics.
Data collection
and processing |
Primmed vault |
Committed
vault |
Half vault |
Magnification | ×81,000 | ×130,000 | ×81,000 |
Voltage (kV) | 300 | 300 | 300 |
Electron exposure (e−/Å2) |
30 | 35 | 30 |
Defocus range (μm) |
−1.5/−3.5 | −1.5/−3.5 | −1.5/−3.5 |
Pixel size (Å) | 1.78 | 1.07 | 1.78 |
Symmetry imposed |
D39 | C1 | C1 |
Initial particle images (n) |
34,822 | 207,815 | 34,822 |
Final particle images (n) |
9793 | 11,666 | 7539 |
Map resolution (Å) |
3.7 | 7.9 | 9.3 |
FSC threshold | 0.143 | 0.143 | 0.143 |
Map resolution range (Å) |
3–8 | 7–13 | 8–14 |
Refinement | |||
Initial model used (PDB code) |
4HL8 | – | – |
B factors (Å2) | −156.45 | – | – |
RMS deviations | |||
Bond lengths (Å) |
0.07 | – | – |
Bond angles (°) | 0.81 | – | – |
Validation | |||
MolProbity score |
20.27 | – | – |
Ramachandran plot |
|||
Favored (%) | 88.24 | – | – |
Allowed (%) | 11.25 | – | – |
Outliers (%) | 0.52 | – | – |
Databases | |||
EMDB | EMD-13478 | EMD-13483 | EMD-13482 |
PDB | 7PKR | – | – |