Table 5.
Event | Sensor Type | Device | N | Application | TI | Device Performance | Factory | References |
---|---|---|---|---|---|---|---|---|
Vulvar lips separation |
Magnetic sensor | Foalert, C6 birth control |
22 80 53 |
Vulva (suture) | 0 h | Se = 100; PPV = 95% | Sisteck Srl, Sassuolo, Italy https://www.foalingalarm.net/ |
Paolucci et al. [53] Paolucci et al. [54] Marchesi et al. [55] |
Magnetic sensor and GPS collar | GPS-CAL | 26 | Vulva (suture) + neck collar (GPS) | 0 h | Se = 100%; PPV = 100% | Sisteck Srl, Sassuolo, Italy SiRF Technology, San Jose, California, USA |
Calcante et al. [56] | |
Device expulsion |
Light and temperature | OraNasco® | 120 15 117 83 |
Vagina | 0 h | Se = 86.30% | Kronotech Srl, Campoformido, Italy https://www.oranasco.it/ |
Palombi et al. [57] Rossi et al. [58] Crociati et al. [59] Crociati et al. [60] |
Light | iVET® | 167 | Vagina | 0 h | Se = 78%; Sp = 93% | iVET®-Geburtsüberwachung für Kühe https://www.nrw-agrar.de/projekt/piloterprobung-des-geburtssensors-ivet-bei-milchkuehen-geburtsueberwachung/ |
Henningsen et al. [61] | |
Temperature | Gyuonkei | 625 | Vagina | 0 h | n.a. | Remote Inc., Oita, Japan http://www.gyuonkei.jp/ |
Sakatani et al. [49] | |
Temperature | Vel’Phone® | 211 241 |
Vagina | 0 h | n.a. | Medria, Châteaugiron, France https://www.medria.fr/en/solutions/velphone/ |
Ricci et al. [50] Choukeir et al. [62] |
|
54 | 0 h | PPV = 100% | Horvàth et al. [31] |
N: number of animals. TI: time interval between calving alarm and parturition. Se: sensitivity; Sp: specificity; Acc: accuracy; PPV: positive predictive value; NPV: negative predicting value; AUC: area under curve; n.a.: not available.