Skip to main content
. 2022 Feb 8;12(3):405. doi: 10.3390/ani12030405

Table 5.

Devices for calving alarm which identify the onset of stage II of parturition, with performance and references.

Event Sensor Type Device N Application TI Device Performance Factory References
Vulvar
lips separation
Magnetic sensor Foalert,
C6 birth control
22
80
53
Vulva (suture) 0 h Se = 100; PPV = 95% Sisteck Srl, Sassuolo, Italy
https://www.foalingalarm.net/
Paolucci et al. [53]
Paolucci et al. [54]
Marchesi et al. [55]
Magnetic sensor and GPS collar GPS-CAL 26 Vulva (suture) + neck collar (GPS) 0 h Se = 100%; PPV = 100% Sisteck Srl, Sassuolo, Italy
SiRF Technology, San Jose, California, USA
Calcante et al. [56]
Device
expulsion
Light and temperature OraNasco® 120
15
117
83
Vagina 0 h Se = 86.30% Kronotech Srl, Campoformido, Italy
https://www.oranasco.it/
Palombi et al. [57]
Rossi et al. [58]
Crociati et al. [59]
Crociati et al. [60]
Light iVET® 167 Vagina 0 h Se = 78%; Sp = 93% iVET®-Geburtsüberwachung für Kühe
https://www.nrw-agrar.de/projekt/piloterprobung-des-geburtssensors-ivet-bei-milchkuehen-geburtsueberwachung/
Henningsen et al. [61]
Temperature Gyuonkei 625 Vagina 0 h n.a. Remote Inc., Oita, Japan
http://www.gyuonkei.jp/
Sakatani et al. [49]
Temperature Vel’Phone® 211
241
Vagina 0 h n.a. Medria, Châteaugiron, France
https://www.medria.fr/en/solutions/velphone/
Ricci et al. [50]
Choukeir et al. [62]
54 0 h PPV = 100% Horvàth et al. [31]

N: number of animals. TI: time interval between calving alarm and parturition. Se: sensitivity; Sp: specificity; Acc: accuracy; PPV: positive predictive value; NPV: negative predicting value; AUC: area under curve; n.a.: not available.