Skip to main content
. 2022 Jan 25;11(3):412. doi: 10.3390/cells11030412

Figure 3.

Figure 3

Setup of the modular monitoring platform. The bioreactor was perfused with the cell culture medium in a circuit using peristaltic pumps (P2) and the OFM probe within the bioreactor with an isotonic solution using microperfusion pumps (P1), which passed through sensors for online monitoring and was subsequently collected for subsequent offline analysis.