Skip to main content
. 2022 Jan 31;19(3):1647. doi: 10.3390/ijerph19031647

Table 2.

Descriptive (Summary) Statistics Comparison Between the AQY1 Monitors and the Reference (Hinton) Monitor. Results by Device ID may be more meaningful.

Ozone
Data Set O3 Raw AQY1 Data (ppb) O3 Calibrated AQY1 Data (ppb) O3 Reference Monitor (Hinton) Data (ppb) O3 Reference Monitor (Hinton) Data—O3 Raw AQY1 Data (Absolute Difference) O3 Reference Monitor (Hinton) Data—O3 Raw AQY1 Data (Difference in %) O3 Reference Monitor (Hinton) Data—O3 Calibrated AQY1 Data (Absolute Difference) O3 Reference Monitor (Hinton) Data—O3 Calibrated AQY1 Data (Difference in %)
Number of records 163,584 163,584 136,632 Not Applicable Not Applicable Not Applicable Not Applicable
Missing records (%) 31,382 (19.2%) 74,322 (45%) 955 (7%) Not Applicable Not Applicable Not Applicable Not Applicable
Minimum 0 0 0 0 Not Applicable 0 Not Applicable
1st Quartile 23.5 19.6 16 −7.5 −47% −3.4 −21%
Median 33.1 31.3 27 −6.1 −23% −4.3 −16%
Mean 35 32.7 27.2 −7.8 −29% −5.2 −19%
3rd Quartile 44.6 43.9 38 −6.6 −17% −5.6 −15%
Maximum 121 138.7 85 −36 −42% −53.7 −63%
Nitrogen Dioxide
Data Set NO2 Raw AQY1 Data (ppb) NO2 Calibrated AQY1 Data (ppb) NO2 Reference Monitor (Hinton) Data (ppb) NO2 Reference Monitor (Hinton) Data—NO2 Raw AQY1 Data (Absolute Difference) NO2 Reference Monitor (Hinton) Data—NO2 Raw AQY1 Data (Difference in %) NO2 Reference Monitor (Hinton) Data—NO2 Calibrated AQY1 Data (Absolute Difference) NO2 Reference Monitor (Hinton) Data—NO2 Calibrated AQY1 Data (Difference in %)
Number of records 163,584 163,584 136,632 Not Applicable Not Applicable Not Applicable Not Applicable
Missing records (%) 31,382 (19.2%) 67,772 (41%) 3026 (22%) Not Applicable Not Applicable Not Applicable Not Applicable
Minimum −109.0 0.0 0.0 109 Not Applicable 0.0 0%
1st Quartile −11.0 0.0 2.8 13.8 493% 2.8 100%
Median −2.4 0.0 4.8 7.2 150% 4.8 100%
Mean −3.4 5.6 7.3 10.7 147% 1.7 23%
3rd Quartile 6.6 5.5 8.8 2.2 25% 3.3 38%
Maximum 208.5 110.9 45.7 −162.8 −356% −65.2 −143%
Particulate Matter with a Diameter Less than 2.5 μm
Data Set PM2.5 Raw AQY1 Data (ug/m3) PM2.5 Calibrated AQY1 Data (ug/m3) PM2.5 Reference Monitor (Hinton) Data (ug/m3) PM2.5 Reference Monitor (Hinton) Data—NO2 Raw AQY1 Data (Absolute Difference) PM2.5 Reference Monitor (Hinton) Data—NO2 Raw AQY1 Data (Difference in %) PM2.5 Reference Monitor (Hinton) Data—NO2 Calibrated AQY1 Data (Absolute Difference) PM2.5 Reference Monitor (Hinton) Data—NO2 Calibrated AQY1 Data (Difference in %)
Number of records 163,584 163,584 136,632 Not Applicable Not Applicable Not Applicable Not Applicable
Missing records (%) 24,677 (15%) 62,269 (38%) 241 (0.18%) Not Applicable Not Applicable Not Applicable Not Applicable
Minimum 0 0 0 0 Not Applicable 0 Not Applicable
1st Quartile 1.8 2.7 4.2 2.4 57% 1.5 36%
Median 3.1 7.7 8 4.9 61% 0.3 4%
Mean 4.3 11.2 9 4.7 52% −2.2 −24%
3rd Quartile 5.3 15.6 12.2 6.9 57% −3.4 −28%
Maximum 866.7 156.2 77 −789.7 −1026% −79.2 −103%
Particulate Matter with a Diameter Less than 10 μm
Data Set PM10 Raw AQY1 Data (ug/m3) PM10 Calibrated AQY1 Data (ug/m3) PM10 Reference Monitor (Hinton) Data (ug/m3) PM10 Reference Monitor (Hinton) Data—NO2 Raw AQY1 Data (Absolute Difference) PM10 Reference Monitor (Hinton) Data—NO2 Raw AQY1 Data (Difference in %) PM10 Reference Monitor (Hinton) Data—NO2 Calibrated AQY1 Data (Absolute Difference) PM10 Reference Monitor (Hinton) Data—NO2 Calibrated AQY1 Data (Difference in %)
Number of records 163,584 163,584 136,632 Not Applicable Not Applicable Not Applicable Not Applicable
Missing records (%) 34,883 (21%) 68,098 (42%) 321 (2.4%) Not Applicable Not Applicable Not Applicable Not Applicable
Minimum 0 0 0 0 Not Applicable 0 0%
1st Quartile 3.5 7 11 7.5 68% 4 36%
Median 5.6 17.5 18 12.4 69% 0.5 3%
Mean 7.24 23.14 20.83 13.59 65% −2.31 −11%
3rd Quartile 8.7 31.9 27 18.3 68% −4.8 −18%
Maximum 968.7 971.7 721 −247.7 −34% −250.7 −35%