The sensitivity of ECT, Pcr, and BCT of high packages (H ≥ 400, L ≤ 200) regarding the grammage of liners and fluting.

Grammage Perturbed Layer ECT PcrL PcrB BCT
100-160-100 liner 0.257 0.433 0.419 0.300
fluting 0.737 0.194 0.225 0.604
160-80-160 liner 0.577 0.330 0.305 0.513
fluting 0.405 0.222 0.300 0.366
140-100-140 liner 0.538 0.435 0.407 0.510
fluting 0.641 0.203 0.263 0.536