Skip to main content
. 2022 Feb 8;11(3):881. doi: 10.3390/jcm11030881

Table 4.

aPNea score and NEWS2 score discrimination and calibration performances in the development and validation cohorts.

Development Cohort
n = 128
Validation Cohort
n = 330
AUROC (95% CI)
aPNea score model 0.86 (0.78–0.93) 0.79 (0.73–0.84)
NEWS2 score model 0.72 (0.59–0.85) 0.81 (0.75–0.87)
De Long’s test p-value 0.025 0.443
Brier score (95% CI)
aPNea score model 0.108 (0.071–0.145) 0.148 (0.124–0.172)
NEWS2 score model 0.132 (0.092–0.171) 0.131 (0.109–0.152)
Wald’s test p-value 0.088 0.073
Spiegelhalter test z-score (p-value)
aPNea score model −0.010 (0.992) 1.267 (0.205)
NEWS2 score model −0.045 (0.964) −1.559 (0.119)

AUROC, area under the receiver operating characteristic curve; CI, confidence interval.