Skip to main content
. 2021 Dec 28;12:e86. doi: 10.34172/jlms.2021.86

Table 1. Clinical Trial Studies Selected for Meta-analysis of 1064 nm Wavelength PBMT .

Categorical Diagnosis
Reference
Groups 1064 nm Laser Session Treatment & Follow-up PEDroScore a Outcome
Knee Knee osteoarthritis
3307439326;
2020
laser + ET n = 20
sham laser + ET n = 20
(double-blinded)
Analgesic: 12 W, 12 J/cm2 25 Hz for 300 J
Biomodulatory: 12 W, 120 J/cm2for 3000 J
Treatment: 5 x/wk 2 wk
Follow-up: EOT, 6 wk
7* Pain reduced (VAS & WOMAC)
ROM increased
Femoral cartilage thickness increased
Knee osteoarthritis
3017843237;
2019
laser n = 30
ET n = 30
CPT n = 30
(single-blinded)
5W, 30Hz, 70% duty, 60 J/cm2, 2400 J Treatment: 3x/wk 12 wk
Follow-up: EOT, 12 wk
6* Pain reduced
Stiffness in knee reduced (WOMAC stiffness)
ROM increased
Juvenile rheumatoid arthritis
3001619328;
2018
laser + ET n = 15
sham laser + ET n = 15
(double-blinded)
3 kW peak power, 10.5 W average, 120-150 µs, 20-30Hz, 10 J/cm2, 60 cm2 spot size, 15J per point to 10 points, 1500 J total
8 m/session
Treatment: 3x/wk 4wk
Follow-up: EOT, 12wk
5* Pain reduced
Gate improved (GAITrite)
Hemophilic arthropathy
2797659135;
2018
laser + PT n = 15
sham laser + PT n = 15
(single-blinded)
Power level not described, 610 mJ/cm2, 750 J/knee total to both knees
8m/session
Treatment: 3/wk 12 wk
Follow-up: EOT
6* Pain reduced
Gait improved
Knee Osteoarthritis
2807850336;
2017
laser + GCS + ET n = 23
GCS + ET n = 22
ET n = 22
(single-blinded)
3 kW peak power, 10.5 W average, 510–1780 mJ/cm2, < 120 μs, 10-30 Hz, 0.2cm2 spot size, 3000 J total
7 m/session
Treatment: 2x/wk 6wk
Follow-up: EOT, 3 mon
6* Pain reduced (WOMAC)
Synovial thickness reduced
Knee osteoarthritis
2809671134;
2016
laser n = 37
sham laser n = 35
(single-blinded)
3x analgesic sessions: 12 W, 12 J/cm2, 300 J, 25 cm2 treatment area
2 m, 25 Hz
4x bio stimulatory sessions: 12 W, 120 J/cm2, 3000 J, 25 cm2 treatment area, 10 m
Treatment: 7d
Follow-up: EOT, 1mo, 3mos
5 Pain reduced (& dolorimetry)
Spine Non-specific lower back pain
3117830644;
2020
laser n = 20
LLLT n = 20
control n = 20
(single-blinded)
Laser: 12 W, 150 J/cm2, 1 cm2 diameter, 1200 J total, 15 m/session

LLLT: 850 nm, 800 mW, 1cm spot, 1 kHz, 80% duty, average of 50 J/cm2, 1200 J total
30 m/session
Treatments:
Laser: 2x/wk 12wk
LLLT: 2x/wk 12wk
Follow-up: EOT
6* Pain reduced
Disability reduced
Lumbar mobility improved
ROM increased
QoL improved
Cervical disc herniation
3214703732;
2019
laser + ET n = 20
ultrasound + TENS + ET n = 20
(single-blinded)
3 kW peak power, 10-40 Hz, 360-1780 mJ/cm2, 120-150 μs, 5 mm diameter
analgesic phase at 8 W, 5 J/cm2, 25 Hz, 1850 J total
15 m/session
Treatment: 5x/wk 4 wk
Follow-up: EOT
5* Pain reduced
QoL improved
ROM increased
Cervical spondylosis
344388332;
2019
laser + ET n = 42
ultrasound + TENS + ET n = 42
(single-blinded)
3 kW peak power, 120-150 μs, 10-40 Hz, 510-1780 mJ/cm2, 5 mm spot, 2050 J total
30 m/session
Treatment: 2x/wk 12 wk
Follow-up: 4 wk
4* Pain reduced
ROM increased
Disability reduced
(laser the most effective)
Lower lumbar disc degeneration
3017441840;
2018
laser n = 18
sham laser n = 17
LLLT n = 16
sham LLLT n = 17
(single-blinded)
Laser: 10 W, 60 J/cm2, 1200 J total, 10 m/session

LLLT: 65 mW, 785 nm, 8 J/cm2, 8 m/session
Treatment: 5x/wk 3wks
Follow-up: EOT, 1 mon, 3 mon
8 No benefits by VAS scores, disability indices, or questionnaires
Lumbar disc protrusion
2885450045;
2018
laser + spinal decompression n = 32
spinal decompression n = 31
12 W, 150 J/cm2, 1 cm spot, 7500 J total: fast manual scanning 3000 J, then 15000 J, then slow manual scanning 3000 J
10 m/session
Treatment: 5x/wk 2 wk
Follow-up: EOT, 4 wk
6 Pain reduced
ROM increased
Chronic neck pain
2691468429;
2016
laser + ET n = 30
placebo + ET n = 30
(double-blinded)
3 kW peak power, 510-1780 mJ/cm, 120-150 μs, 10-40 Hz, 0.5 cm diameter, and 0.2 cm2 spot size, 2250 J total over 3 phases (see manuscript), 75 cm2 treated area
15 m/session
Treatment: 2x/wk 6wk
Follow-up: EOT
4* Disability reduced
ROM increased
Shoulder
Arm
Subacromial Impingement Syndrome
33400001224;
2021
laser + exercise n = 32
sham laser + exercise n = 31
(double-blinded)
3 kW peak power, 360-1780 mJ/cm2, 40 Hz, 2781 J total
25 m/session
Treatment: 5x/wk 3wk
Follow-up: EOT, 12 wk
8 Pain reduced
ROM increased
Strength increased
Daily activity increased
Subacromial impingement Syndrome
2722057739;
2016
laser + MT + KT + EX n = 19
ET n = 15
KT +EX n = 20
MT + KT + EX n = 16
(single-blinded)
3 kW peak power; 5 mm spot diameter; 3 s phases: fast manual scanning 100cm2/30s of the zones of muscular contracture, particularly trapezius, supraspinatus, and deltoid during shoulder abduction, for 1000 J/cm2, 2nd phase 50 J to each of 4 trigger points; final phase with slow manual scanning 100 cm2/60 s to same first phase areas for 1000 J total - 510, 610, and 710 mJ/cm2 for a total of 2050 J.
30 m/session.
Treatment: 3x/15d
Follow-up: EOT
6* Pain reduced (SPALDI)
Disability reduced
ROM increased
Lateral epicondylitis
2990093838;
2016
laser n = 31
bandage n = 34
(single-blinded)
75 s at 4 W for 6 J/cm2
Analgesic: targeting painful areas 4 sessions.
Biostimulatory: 6x sessions 6 W 100-150 J/cm2
12 m/session
Treatment: 5x/wk 2wk
Follow-up: 6 wk
5* Pain reduced, disability reduced, hand strength increased, and QoL improved
Foot Calcaneal spur
3147809525;
2020
laser + ET n = 21
sham laser + ET n = 21
(double-blinded)
3 kW peak power, 360–1780 mJ/cm2, 150 μs, 10.5 W average power, 10-40 Hz, 0.2 cm2 spot size, 1281 J total, 10 m/session Treatment: 5x/wk 3 wk
Follow-up: 4 wk, 12 wk
7* Improved pedographic measures
Plantar fasciitis
3251301843;
2020
laser n = 51
LLLT n = 51
(single-blinded)
laser: 12 W, 120 J/cm2, 3000 J total, 25 cm2 spot, 7m/session
LLLT; 785 nm, 50 mW, 50-60 Hz, 4 J/cm2, 140 J total, 35 cm2 spot, 7 m/session
Treatment: 3x/wk 8x 3wk
Follow-up: EOT, 4 wk
8* No statistical difference in pain
Laser more effective than LLLT in the opinion of participants
Plantar fasciitis
2962788831;
2018
laser n = 35
LLLT n = 35
(single-blinded)
laser: 3x analgesic: 8 W, 75s, 6J/cm2, 150 J total; 6x bio-stimulation: 30s, 6 W, 150 J/cm2 dose
LLLT: 904 nm, 240 mW, 5000 Hz, 0.16 W/cm2, 160 s per session, 680 J total
Treatment: 3x/wk 3 wk
Follow-up: EOT
8* Pain reduced (VAS)
Function improved
QoL improved
(laser all more than LLLT)
Wound Caesarian healing in diabetic women
2970670846;
2018
laser n = 20
sham laser n = 20
10.5 W, 0.5-1.8 J/cm2, 10-40 Hz, 150 μs pulses 10–40 Hz, 150 J first phase, then 1 cm away from wound 20 J per each of 12 points, last phase, same as first, but slow scanning Treatment: 3x/wk 6 wk
Follow-up: EOT
5* Wound appearance improved
Post-burn pruritus
2823307130;
2017
laser n = 25
sham laser n = 24
(double-blinded)
3k W peak power, 0.5-1.8 J/cm2, 150 μs pulses 10–40 Hz, 0.2 cm2spot size, 3000 J Treatment: 3/wk 6 wk
Follow-up: EOT, 12 wk
10 Itch severity reduced
QoL improved
Pain reduced (VAS)
Gynecological Primary dysmenorrhea
2918428127;
2017
laser n = 26
PEMF n = 26
(double-blinded)
3 kW peak power, 810-1780 mJ/cm2, 150 μs, 10–40 Hz, 880 J total
15m/session
3 treatments per cycle for 3 cycles (3 mon)
Follow-up: EOT
4* Pain reduced
Prostaglandins reduced
Bone Osteoporosis & osteopenia by DEXA scan
2906875642;
2018
laser + ET n = 25
sham laser + exercise n = 25
laser only n = 25
placebo n = 25
(single-blinded)
10.5 W, 510-1780 mJ/cm2, 150µs pulses 10-30 Hz, spot size 0.2 cm2, 3,000J delivered 2x phases: fast scanning at 510, 610, and 710 mJ/cm2 for 1500 J, then slow scanning
18 m/session
Treatment: 3x/wk 24 wk
Follow-up: EOT, 1 y
Z* Lumbar bone mineral density improved

aDatabase retrieved and confirmed PEDro scores based on 10-point scale. ROM-range of motion.