Skip to main content
. 2022 Feb 3;22(3):1160. doi: 10.3390/s22031160

Table 7.

Task and performance comparisons between the presented study and previous studies on breast cancer detection.

Reference
(Year)
Task Dataset Used Ave_Sen
(%)
Ave_Spe
(%)
Acc
(%)
AUC
This study
(2022)
Classification of BI-RADS 0, 1, 2, 3, 4A, 4B, 4C, 5
(8 categories)
Private (1490 cases, 5733 images) 95.31 99.15 94.22 0.972
[8]
(2021)
Malignancy prediction of BI-RADS 4 micro-calcifications
(2 classes)
Private (384 cases, 824 images) 85.3 91.9 - 0.910
[11]
(2021)
Mass malignancy classification
(2 classes)
DDSM (2578 cases, 10,312 images) 89.8 @ 2 FPPI 1 - - -
Private (2807 cases, 11,228 images) 96.2 @ 2 FPPI - - -
[13]
(2020)
BI-RADS 2-5 classification for breast masses
(4 categories)
DDSM
(500 images)
84.5 94.25 84.5 -
[22]
(2019)
Normal, benign calcification,
benign mass, malignant calcification, malignant mass
(5 classes)
DDSM +
CBIS-DDSM
(2339 images)
- - 91 0.98

1 FPPI: false positive per image.