Skip to main content
. 2022 Jan 31;22(3):1102. doi: 10.3390/s22031102

Table 1.

Information regarding the real signal waveforms with the mean sensor resistance.

Input Condition Ethanol
Concentration [ppm]
Figure 5a Figure 6a
Measurement Time [s] Mean Sensor Resistance [kΩ] Measurement Time [s] Mean Sensor Resistance [kΩ]
Ethanol 50 0~360 166.06~26.93 0~950 60.82~12.83
Air 0 360~720 26.93~154.47 950~1900 12.83~50.98
Replacing Sensor 0 720~900 X 1900~2080 X
Ethanol 50 900~1260 62.46~19.43 2080~3030 74.18~15.35
Air 0 1260~1620 19.43~70.39 3030~3980 15.35~77.57
Replacing Sensor 0 1620~1800 X 3980~4160 X
Ethanol 50 1800~2160 77.41~20.49 4160~5110 102.87~17.17
Air 0 2160~2520 20.49~79.77 5110~6060 17.17~100.62
Replacing Sensor 0 2520~2700 X 6060~6260 X
Ethanol 50 2700~3060 104.68~23.6 6260~7210 62.25~13.26
Air 0 3060~3600 23.6~127.74 7210~8200 13.26~58.97