Table 1.
Technical specifications of the CPT Icone digital cone.
| “Icone” Digital Cone | Technical Characteristics | Maximum Range |
|---|---|---|
| Resolution | 24 bits (Ix/Iy 16 bits) | |
| Cone tip area | 10 cm2 | |
| Available parameters | , Ix/Iy | |
| Memo function | 16 Mbit (8 hrs. CPT operation) | |
| Real-time data processing | ||
| Cone resistance () | 75 MPa | 150 MPa |
| Minimal accuracy for Class 2 | 100 kPa or 5% | |
| Sleeve friction () | 1 MPa | 1.5 MPa |
| Minimal accuracy for Class 2 | 15 kPa od 3% | |
| Pore water pressure (u) | 2 MPa | 3 MPa |
| Minimal accuracy for Class 2 | 25 kPa od 2% | |
| Inclination (Ix/Iy) | 20° | 25° |
| Minimal accuracy for Class 2 | 2° |