“Icone” Digital Cone | Technical Characteristics | Maximum Range |
---|---|---|
Resolution | 24 bits (Ix/Iy 16 bits) | |
Cone tip area | 10 cm2 | |
Available parameters | , Ix/Iy | |
Memo function | 16 Mbit (8 hrs. CPT operation) | |
Real-time data processing | ||
Cone resistance () | 75 MPa | 150 MPa |
Minimal accuracy for Class 2 | 100 kPa or 5% | |
Sleeve friction () | 1 MPa | 1.5 MPa |
Minimal accuracy for Class 2 | 15 kPa od 3% | |
Pore water pressure (u) | 2 MPa | 3 MPa |
Minimal accuracy for Class 2 | 25 kPa od 2% | |
Inclination (Ix/Iy) | 20° | 25° |
Minimal accuracy for Class 2 | 2° |