Skip to main content
. 2022 Jan 25;22(3):934. doi: 10.3390/s22030934

Table 1.

Technical specifications of the CPT Icone digital cone.

“Icone” Digital Cone Technical Characteristics Maximum Range
Resolution 24 bits (Ix/Iy 16 bits)
Cone tip area 10 cm2
Available parameters qc, fs, u2, Ix/Iy
Memo function 16 Mbit (8 hrs. CPT operation)
Real-time data processing
Cone resistance (qc) 75 MPa 150 MPa
Minimal accuracy for Class 2 100 kPa or 5%
Sleeve friction (fs) 1 MPa 1.5 MPa
Minimal accuracy for Class 2 15 kPa od 3%
Pore water pressure (u) 2 MPa 3 MPa
Minimal accuracy for Class 2 25 kPa od 2%
Inclination (Ix/Iy) 20° 25°
Minimal accuracy for Class 2