Table A3.
The number of cycles to failure depending on the load frequency for HPC-1 [22].
| Storage Conditions | ft | Smax | Smin | Nf | log Nf | Mean log Nf |
|---|---|---|---|---|---|---|
| WST | 10 | 0.65 | 0.05 | 24,271 | 4.39 | 4.42 |
| 10 | 0.65 | 0.05 | 31,153 | 4.49 | ||
| 10 | 0.65 | 0.05 | 23,499 | 4.37 | ||
| WST | 5 | 0.65 | 0.05 | 16,208 | 4.21 | 4.22 |
| 5 | 0.65 | 0.05 | 22,887 | 4.36 | ||
| 5 | 0.65 | 0.05 | 12,329 | 4.09 | ||
| WST | 1 | 0.65 | 0.05 | 13,931 | 4.14 | 4.05 |
| 1 | 0.65 | 0.05 | 9944 | 4.00 | ||
| 1 | 0.65 | 0.05 | 10,396 | 4.02 | ||
| WST | 0.35 | 0.65 | 0.05 | 3880 | 3.59 | 3.69 |
| 0.35 | 0.65 | 0.05 | 4494 | 3.65 | ||
| 0.35 | 0.65 | 0.05 | 6779 | 3.83 |