Table 1.
Standard and Modified Fast Fit-Testing Protocols for Filtering Facepiece Respirators
Fit-Test Exercise | Standard Protocol | Modified #Fast Protocol |
---|---|---|
Normal breathing, seconds | 60 | … |
Deep breathing, seconds | 60 | … |
Turning head side-to-side, seconds | 60 | 30 |
Moving head up-and-down, seconds | 60 | 30 |
Talking, seconds | 60 | 30 |
Grimacing, seconds | 15 | …. |
Bending over, seconds | 60 | 30 |
Normal breathing, seconds | 60 | … |
Total time, min | 7.2 | 2.5 |
Ambient purge, ambient sample, mask sample | Beginning, before every exercise, and at the end | Beginning and end only |
Sample time, seconds | 40 | 30 |