Skip to main content
. 2022 Feb 10;2022:7946239. doi: 10.1155/2022/7946239

Table 2.

Comparison of mean ± SD values of fracture toughness (KIc) between all materials after wet or dry storage, analysed by independent t-test.

Storage time 1 day 7 days 60 days
Condition Dry Wet P value Dry Wet P value Dry Wet P value
Aura (bulk-fill) 16.80 ± 1.10A 17.74 ± 1.43A 0.235 17.76 ± 1.82A 15.16 ± 0.78A 0.009 16.82 ± 1.80A 13.55 ± 1.17A 0.001
Tetric Evoceram (bulk-fill) 15.87 ± 2.15A 17.10 ± 1.86A 0.959 14.39 ± 1.07A 14.88 ± 2.44A 0.686 18.31 ± 2.56A 15.32 ± 2.97A 0.107
G-ænial Universal Flo 22.97 ± 3.11B 19.25 ± 2.93A 0.074 23.4 ± 6.11B 22.09 ± 1.49B 0.630 27.94 ± 5.39B 26.58 ± 5.37B 0.671
GC Kalore 16.85 ± 0.86A 16.8 ± 2.01A 0.314 14.26 ± 1.77A 14.89 ± 3.14A 0.688 18.38 ± 2.64A 15.87 ± 3.49A 0.190
P value <0.001 0.257 0.001 <0.001 <0.001 <0.001

Significance level of independent t-test between wet and dry storage (P value< 0.05). Different uppercase letters show significant difference between materials in each condition (column).