Skip to main content
. 2022 Feb 20;211(2-3):105–117. doi: 10.1007/s00430-022-00730-z

Table 2.

Determination of assay sensitivity for nine SARS-CoV-2 rapid antigen tests in SARS-CoV-2 PCR-positive respiratory swabs classified as omicron

Assay Sensitivity (%) 95% CI (%) True positive/total
Test 1 22.22 15.16–31.36 22/99
Test 2 35.64 26.99–45.35 36/101
Test 3 31.68 23.42–41.29 32/101
Test 4 35.64 26.99–45.35 36/101
Test 5 47.52 38.06–57.18 48/101
Test 6 43.00 33.73–52.78 43/100
Test 7 29.70 21.67–39.23 30/101
Test 8 51.49 41.86–61.00 52/101
Test 9 57.43 47.69–66.62 58/101

Binomial confidence intervals were computed using the Wilson score interval