Skip to main content
. 2000 Mar;38(3):1279–1282. doi: 10.1128/jcm.38.3.1279-1282.2000

TABLE 2.

Sensitivity of ELISAs for syphilis in comparison with the IgM specific immunofluorescence test (19S IgM FTA-ABS)a

Trade name (company) Trepanostika (Organon) ICE Syphilis (Murex) Enzygnost Syphilis (Behring) Pathozyme Syphilis Competition (Omega) Bioelisa Syphilis (Biokit) Trep-Chek (Phoenix) TmpA-ELISA (Eurodiagnostica) Captia Syphilis G (Trinity) Captia Syphilis M (Mercia) 19S IgM FTA-ABS
No. nonreactive/total no. 12/52 13/52 16/52 16/52 17/41 15/41 16/31 24/31 7/52 5/52
Sensitivity (%) 76.9 75.0 69.2 69.2 67.3 63.4 48.5 22.6 86.5 90.4
Sensitivity (95% confidence interval) 63.2–87.5 61.1–86.0 54.9–81.3 54.9–81.3 52.9–79.7 46.9–77.9 30.2–66.9 9.6–41.1 74.2–94.4 79.0–96.8
a

Comparative evaluation was performed with 52 sera from patients with primary syphilis, all nonreactive in the MHA-TP test.