Skip to main content
. 2022 Feb 16;8(2):e08970. doi: 10.1016/j.heliyon.2022.e08970

Table 3.

Estimation of potential recovered material from PV panel in Bangladesh.

Project name Capacity (MW) Estimated Weight of panel (tonne) Recovered material (tonne)
Glass Aluminum Silicon Copper
Solar parks 38.4 3072 2263.744 245.760 129.976 23.894
Rooftop solar except NEM 41.766 3341.28 2462.175 267.302 141.369 25.988
Net metering rooftop solar 16.207 1296.56 955.429 103.724 54.857 10.084
Solar irrigation 42.408 3392.64 2500.022 271.411 143.542 26.387
Solar mini-grid 5.656 452.48 333.430 36.198 19.144 3.519
Solar charging stations 0.278 22.24 16.388 1.779 0.940 0.172
Solar drinking water system 0.062 4.96 3.655 0.396 0.209 0.038
Solar powered telecom BTS 8.06 644.8 475.150 0.051 27.281 5.015
Solar home system 251.64 20131.2 14834.600 1610.496 851.751 156.580
Solar street light 10.59 847.2 624.298 67.776 35.845 6.589
Total 33205.36 24468.896 2656.428 1404.918 49.882