Skip to main content
. 2022 Feb 8;8:792322. doi: 10.3389/fvets.2021.792322

Table 2.

Sensitivity of the real-time PCR.

Number of
DNA copies
(copies/assay)
Triplex real-time PCR Ct valuea
(mean ±SD)
Uniplex real-time PCR Ct valueb
(mean ±SD)
FPV FCV FHV-1 FPV FCV FHV-1
5 × 107 14.39 ± 0.25 14.44 ± 0.01 16.17 ± 0.11 14.32 ± 0.25 14.81 ± 0.15 16.11 ± 0.23
5 × 106 18.02 ± 0.45 18.46 ± 0.05 19.62 ± 0.22 18.32 ± 0.05 18.18 ± 0.25 19.69 ± 0.07
5 × 105 21.73 ± 0.16 21.53 ± 0.22 22.47 ± 0.36 21.93 ± 0.02 21.37 ± 0.03 22.82 ± 0.10
5 × 104 25.93 ± 0.06 25.30 ± 0.02 25.98 ± 0.01 25.50 ± 0.66 24.86 ± 0.03 26.28 ± 0.12
5 × 103 29.84 ± 0.13 28.42 ± 0.03 29.40 ± 0.06 27.62 ± 0.16 28.07 ± 0.52 29.95 ± 0.03
5 × 102 32.91 ± 0.21 31.94 ± 0.02 32.61 ± 0.03 31.76 ± 0.35 31.60 ± 0.42 32.98 ± 0.19
5 × 101 35.67 ± 0.83 35.62 ± 0.77 34.93 ± 0.53 34.08 ± 0.33 33.41 ± 0.08 35.25 ± 0.16
a

The result was considered positive if mean Ct value ≤ 36.

b

Each reaction was performed in triplicate, and the results are shown as the mean ± SD.