Absorbed cumulative radiation dose estimates of [131I]SGMIB-2Rs15d and iso-[131I]SGMIB-VHH_1028 to kidneys and tumors for a hypothetical dose of 37 MBq.

Animal model sdAb Prosthetic agent Cumulative activity (µCi*h/g) Radiation dose (cGy)
Kidney Tumor Kidney Tumor
SKOV-3 VHH_1028 iso-[131I]SGMIB 445 2326 192 1003
2Rs15d [131I]SGMIB 849 1541 366 665
BT474 VHH_1028 iso-[131I]SGMIB 1000 8805 431 3798
2Rs15d [131I]SGMIB 2127 2965 917 1279

Estimates were based on biodistribution data in Tables 1 and 2. Cumulative radioactivity were calculated using the trapezoid integration method by calculating area under the activity/g tissue curves, extrapolating to when negligible activity remained. They were converted to absorbed cumulative dose by multiplying the equilibrium absorbed dose constant for 131I, 0.4313 g*cGy/(µCi*h).