Skip to main content
. 2022 Jan 29;12(2):347. doi: 10.3390/diagnostics12020347

Table 3.

Diagnostic accuracy of whole-body computed tomography for ovarian lesions.

FN TP TN FP Accuracy Sensitivity Specificity PPV NPV
Malignant vs. Benign
Solid/SC 0 11 48 1 98.3 (91.1–100.0) 100.0 (71.5–100.0) 98.0 (89.1–99.9) 91.7 (61.5–99.8) 100.0 (92.6–100.0)
Bilateral 8 3 44 5 78.3 (65.8–87.9) 27.3 (6.0–61.0) 89.8 (77.8–96.6) 37.5 (8.5–75.5) 84.6 (71.9–93.1)
Combined 8 3 49 0 86.7 (75.4–94.1) 27.3 (6.0–61.0) 100.0 (92.7–100.0) 100.0 (29.2–100.0) 86.0 (74.2–93.7)
Metastasis vs. Primary
Solid 0 4 6 1 90.9 (58.7–99.8) 100.0 (39.8–100.0) 85.7 (42.1–99.6) 80.0 (28.4–99.5) 100.0 (54.1–100.0)
Bilateral 2 2 6 1 72.7 (39.0–94.0) 50.0 (6.8–93.2) 85.7 (42.1–99.6) 66.7 (9.4–99.2) 75.0 (34.9–96.8)
Combined 2 2 7 0 81.8 (48.2–97.7) 50.0 (6.8–93.2) 100.0 (59.0–100.0) 100.0 (15.8–100.0) 77.8 (40.0–97.2)