Ventilator and Respiratory Parameters during Proning

N = 309 T1 T2 T3 T4
Prone Episode Duration, h 23 (14 – 49)
I/O from Intubation, mL 1600 (200 – 5000) 2500 (200 – 6500)
I/O from Admission, mL 1800 (-500 – 6000) 2800 (-300 – 7500)
PEEP, cm H2O 12 (10 – 14) 12 (10 – 14) 12 (10 – 14) 12 (10 – 14)
FiO2 70 (60 – 100) 70 (60 – 100) 60 (50 – 80) 60 (50 – 80)
Tidal Volume, mL 420 (360 – 460) 400 (360 – 450) 400 (360 – 460) 400 (360 – 460)
Respiratory Rate 24 (20 – 28) 24 (20 – 28) 25 (20 – 30) 25 (20 – 30)
Plateau Pressure, cm H2O 28 (25 – 30) 28 (25 – 30) 27 (25 – 29) 28 (25 – 30)
Static Compliance, mL/cm H2O 26 (22 – 33) 27 (22 – 32) 29 (23 – 33) 26 (21 – 32)
Driving Pressure, cm H2O 15 (13 – 19) 15 (12 – 18) 15 (12 – 18) 15 (13 – 19)
pH 7.34 (7.29 – 7.4) 7.35 (7.29 – 7.4) 7.35 (7.29 – 7.4) 7.35 (7.28 – 7.4)
PaO2, mm Hg 78 (67 – 101) 79 (67 – 101) 83 (70 – 07) 83 (71 – 107)
PaCO2, mm Hg 47 (41 – 54) 47 (42 – 55) 48 (43 – 55) 48 (42 – 55)
PaO2/FiO2, mm Hg 115 (80 – 148) 114 (86 – 156) 140 (93 – 205) 137 (95 – 197)

*T1: Supine prior to prone; T2: start of prone; T3: end of prone; T4: after return to supine