Table 4.
Mean ± SD of parameters measured by NeuronJ and ACCMetrics.
| Control | DED with ocular pain | Mean difference & 95%CI | t Test | |||
|---|---|---|---|---|---|---|
| t Value | P Value | |||||
| CNFD (n/mm2) | NeuronJ | 26.5 ± 6.9 | 23.5 ± 8.1 | 3.0 (1.6–4.4) | 4.1 | <0.001 |
| ACCMetrics | 30.7 ± 8.9 | 23.8 ± 8.6 | 6.9 (5.2–8.6) | 8.1 | <0.001 | |
| CNBD (n/mm2) | NeuronJ | 67.0 ± 20.4 | 46.0 ± 21.3 | 20.9 (16.9–24.9) | 10.4 | <0.001 |
| ACCMetrics | 46.0 ± 24.0 | 35.7 ± 23.3 | 10.3 (5.8–14.8) | 4.5 | <0.001 | |
| CNFL (mm/mm2) | NeuronJ | 23.7 ± 4.1 | 19.3 ± 4.3 | 4.5 (3.7–5.3) | 11.0 | <0.001 |
| ACCMetrics | 18.6 ± 3.4 | 15.2 ± 3.8 | 3.4 (2.7–4.1) | 9.7 | <0.001 | |
Results are expressed as mean ± SD. DED, dry eye disease.