Printing parameters of the SLM process for the training and validation set.

Printing Parameters for the Training Set
Laser Power
120 W 140 W 160 W
Spot size 45 μm P1 P2 P3 Scan speed = 900 mm/s
60 μm P4 P5 P6
75 μm P7 P8 P9
45 μm P10 P11 P12 Scan speed = 1000 mm/s
60 μm P13 P14 P15
75 μm P16 P17 P18
45 μm P19 P20 P21 Scan speed = 1100 mm/s
60 μm P22 P23 P24
75 μm P25 P26 P27
Printing Parameters for the Validation Set
Specimens ID Laser Power (W) Scan Speed (mm/s) Spot Size (μm)
P28 130 950 50
P29 130 950 55
P30 130 1050 65
P31 130 1050 70
P32 150 950 50
P33 150 950 55
P34 150 1050 65
P35 150 1050 70
P36 135 1025 52
P37 155 975 67