Table 1.
Printing parameters of the SLM process for the training and validation set.
Printing Parameters for the Training Set | |||||
Laser Power | |||||
120 W | 140 W | 160 W | |||
Spot size | 45 μm | P1 | P2 | P3 | Scan speed = 900 mm/s |
60 μm | P4 | P5 | P6 | ||
75 μm | P7 | P8 | P9 | ||
45 μm | P10 | P11 | P12 | Scan speed = 1000 mm/s | |
60 μm | P13 | P14 | P15 | ||
75 μm | P16 | P17 | P18 | ||
45 μm | P19 | P20 | P21 | Scan speed = 1100 mm/s | |
60 μm | P22 | P23 | P24 | ||
75 μm | P25 | P26 | P27 | ||
Printing Parameters for the Validation Set | |||||
Specimens ID | Laser Power (W) | Scan Speed (mm/s) | Spot Size (μm) | ||
P28 | 130 | 950 | 50 | ||
P29 | 130 | 950 | 55 | ||
P30 | 130 | 1050 | 65 | ||
P31 | 130 | 1050 | 70 | ||
P32 | 150 | 950 | 50 | ||
P33 | 150 | 950 | 55 | ||
P34 | 150 | 1050 | 65 | ||
P35 | 150 | 1050 | 70 | ||
P36 | 135 | 1025 | 52 | ||
P37 | 155 | 975 | 67 |